MicroStar DC CRS Series DC power supplies

  • Microprocessor-based controls for accuracy and repeatability
  • MicroStar DC Series soft-touch keypad and digital displays
  • Selectable current, voltage or cross-over regulation modes
  • Output voltage and current tolerance limit setting with alarms
  • Ampere time and real time cycle control via front panel
  • Resettable ampere time totalizer with password protection
  • Selectable ampere time and real time counter resolutions
  • Audible alarms for end-of-cycle and out-of-tolerance conditions
  • Save/Recall/Delete settings feature (up to 10 saved setups)
  • Front panel calibration control
  • Built in fault detection for over-temperature and AC power failure conditions
  • Minimum suggested setting: 5% of maximum rating of power supply
  • Ripple: <1% RMS of maximum rated output voltage
  • RS485 Serial control standard on all models
  • Windows-based control program
  • Forced air cooling. Airflow from front to rear through sealed heat sink tunnel
  • Environmentally sealed to protect power supply from harsh environments
  • Powder coated aluminum enclosure 7" x 17" 22" (HWD)

 

Option

  • Recipe control - links up to 8 of your saved setups into a recipe. Includes setup looping capabilities
  • Output ramp timer - ramps output up to a desired set point over a user-selected time period
  • Auxiliary ampere time totalizer with relay output. Great for chem-add systems!
  • Analog Interface for PLC control (4-20 mA, 0-5 volt or 0-10 volt signals)
  • Remote MicroStar Interface with 10' of cable
  • Rack mount flanges

 

MicroStar Pulse Series Size Chart

Model

Voltage

(DC)
Average Current
or Maximum DC
(Amps)

Peak Current

(Amps)

Volt
Meter
Resolution

Amp Meter

Resolution

110-120 VAC

1 Phase
50/60Hz

208-240 VAC

1 Phase
50/60Hz

208-240 VAC

3 Phase
50/60Hz

Package

& Cooling

DP 20-5-10 0 - 20
0 - 5 0 - 10
0.1
0.01 A
X
X
A - air
DP 20-10-30 0 - 20
0 - 10 0 - 30 0.1 0.01 A
X X A - air
DP 20-15-30 0 - 20
0 - 15
0 -30 0.1 0.01 A
X X X
A - air
DP 20-30-100 0 - 20
0 - 30
0 -100 0.1 0.1 A
X X X A - air
 DP 20-50-200 0 - 20 0 - 50
0 - 200
0.1  0.1 A  
X X B - air
 DP 20-100-400
0 - 20
0 - 100
0 - 400
0.1  1 A
X B - water
 DP 20-150-300
0 - 20
0 - 150
0 - 300
0.1  0.1 A
X B - water
DP 20-250-400
0 - 20
0 - 250 0 - 400
0.1  1 A
X B - water
 DP 40-5-10
0 - 40  0 - 5
0 - 10
0.1  0.01 A X
X A - air
 DP 40-10-30
0 - 40  0 - 10
0 - 30
0.1  0.01 A X X A - air
 DP 40-15-30
0 - 40  0 - 15
0 - 30
0.1  0.01 A X X A - air
 DP 40-30-100
0 - 40  0 - 30
0 - 100
0.1  0.1 A
X X A - air
 DP 40-50-200
0 - 40  0 - 50
0 - 200
0.1  0.1 A X B - water
DP 40-100-400
0 - 40  0 - 100
0 - 400
0.1  1 A
X B - water

Specifications subject to change without notification

 

More Information>>